Designing a network

This page covers the placement engine: how the algorithm chooses locations, the options on hydrosensenet.SensorNetworkDesigner, and the lower-level functions. New to the package? Start with the quickstart.

How QR column pivoting picks sensors

Arrange your historical record as a matrix X with one row per timestep and one column per candidate location, so each column is that location’s hydrograph. Column-pivoted QR factorizes X while greedily reordering its columns: at every step it selects the column with the largest norm after projecting out everything already selected — the location carrying the most variance that the chosen sensors cannot already explain. The first k pivots are therefore both maximally informative and mutually non-redundant: a gauge whose record closely mirrors an already-selected gauge is skipped, even if it is individually high-variance. The selected columns form a well-conditioned basis for reconstructing the full flow field from k point measurements — exactly what the evaluation step measures.

Design options

design_network() has three knobs you will touch most often:

  • n_sensors — total network size (including any locked-in gauges, see below).

  • evaluate / train_frac — with evaluate=True (default) the record is split chronologically (train_frac=0.7: first 70% train, last 30% test), placement runs on the training window only, and the test window is reconstructed from the selected sensors to give NSE/NNSE and relative-error metrics. evaluate=False places on the full record; no metrics are computed.

  • verbose — prints a step-by-step progress log; set False for scripts.

Columns containing NaN or inf in the training window are excluded from placement (a warning reports how many). Everything in the result — selected indices, labels, per-location metric arrays — still refers to the original column order, and metric arrays carry NaN at excluded locations. An existing_sensors entry pointing at an excluded column raises a ValueError.

import numpy as np
import geopandas as gpd
from hydrosensenet import SensorNetworkDesigner

rng = np.random.default_rng(42)
n_times, n_locs = 400, 30

# Synthetic streamflow: shared basin-scale modes plus local noise
# (the low-rank structure that real river networks exhibit).
modes = rng.standard_normal((n_times, 4))
flows = modes @ rng.standard_normal((4, n_locs))
flows += 0.1 * rng.standard_normal((n_times, n_locs))

locations = gpd.GeoDataFrame(
    {"gauge_id": [f"G{i:03d}" for i in range(n_locs)]},
    geometry=gpd.points_from_xy(
        rng.uniform(-112.0, -109.0, n_locs), rng.uniform(38.0, 41.0, n_locs)
    ),
    crs="EPSG:4326",
)

designer = SensorNetworkDesigner(flows, locations, list(locations["gauge_id"]))
result = designer.design_network(
    n_sensors=8, train_frac=0.7, evaluate=True, verbose=False
)
result.print_summary()

Locking in existing gauges

If part of the network already exists, pass existing_sensors=[...] — integer indices into the column order of your streamflow matrix. Those columns are kept unconditionally; the remaining slots are filled by pivoted QR on the other columns after orthogonalizing them against the fixed ones, so new sensors only chase information the existing gauges do not provide. The result ordering is guaranteed: fixed indices come first in result.selected_indices, in the order you passed them, followed by the QR-ranked additions. If len(existing_sensors) == n_sensors, QR is skipped entirely and the call simply evaluates the network you specified — a convenient way to benchmark a current gauge configuration.

locked = [2, 17]
result_locked = designer.design_network(
    n_sensors=8, existing_sensors=locked, evaluate=False, verbose=False
)
assert list(result_locked.selected_indices[:2]) == locked

Weighting the design

weights= biases selection toward locations you care about. An ndarray with one entry per column scales each hydrograph before the factorization, so a weight of 3 triples a column’s norm and makes it far more likely to be pivoted early; a weight of 0 removes a location from contention.

weights = np.ones(n_locs)
weights[:10] = 3.0  # prioritize the first ten locations
result_weighted = designer.design_network(
    n_sensors=8, weights=weights, evaluate=False, verbose=False
)

Alternatively, pass a file path plus weight_column, and the weights are derived by spatially joining your locations to that dataset via hydrosensenet.calculate_spatial_weights(). The following display-only example needs a downloaded FEMA National Risk Index file; see risk-informed design for the full workflow.

result = designer.design_network(
    n_sensors=8,
    weights="NRI_GDB_Counties.gpkg",  # any file geopandas can read
    weight_column="RISK_SCORE",
)

Using the modular API directly

When you want the raw index selection without the designer’s splitting, evaluation, and result packaging, call hydrosensenet.sensor_placement_qr() on your own training matrix. It has the same weights and fixed_indices semantics and returns the selected column indices, fixed ones first.

from hydrosensenet import sensor_placement_qr

X_train = flows[: int(0.7 * n_times)]
idx = sensor_placement_qr(X_train, n_sensors=8, weights=weights, fixed_indices=[2, 17])
print(idx)

For per-region quotas — for example, guaranteeing coverage in each HUC or state — use hydrosensenet.qr_pivot_selection(). It runs an independent (unweighted) pivoted QR inside each region. region_assignments is a DataFrame with a region_name column (configurable via region_column) and a col_pos column giving each location’s column index; sensors_per_region maps region names to quotas (capped at region size; regions absent from the dict get none). It returns the selected rows of region_assignments plus the flat list of selected column indices.

import pandas as pd
from hydrosensenet import qr_pivot_selection

regions = pd.DataFrame({
    "region_name": np.where(locations.geometry.x < -110.5, "west", "east"),
    "col_pos": np.arange(n_locs),
})
selected_df, selected_idx = qr_pivot_selection(
    X_train, regions, sensors_per_region={"west": 3, "east": 5}
)
print(selected_df[["region_name", "col_pos"]])

Determinism

Placement is fully deterministic: pivoted QR involves no random seed, so the same matrix, weights, and fixed indices always yield the same selection. The seed above only generates the synthetic data. Selected indices are always positions in the column order you supplied, even when the NaN/inf filter excludes some columns from consideration.

Scalability

hydrosensenet.sensor_placement_qr() picks between two factorization paths via its method parameter (default "auto"). For large basins it runs a truncated greedy pivoted QR that performs only the n_sensors elimination steps — O(m·n·k) instead of the full factorization’s O(m·n·min(m, n)) — and selects identical sensors. On an Apple M1 Pro with a 3,000 × 64,954 matrix (HUC2-scale) and 50 sensors, the full path takes ~168 s while the truncated path takes ~14 s. Passing a float32 matrix halves memory on the truncated path. Force a specific path with method="full" or method="truncated"; benchmarks/bench_placement.py in the repository reproduces the comparison on your hardware.